Description: Free DownloadMAZDA 323-1.6i-B6 Adjustment Data Manual in Pdf ebook in pdf files,FunctionThe evaporative canister is equipped with a purge solenoid valve. The control unit switches the solenoid on or off.This controls the amount of vapour purged into the inlet manifold.Specificationssupply voltage: 12 Vresistance: 25 – 35 ohmsDiagnosisCheck connector(s): Inspect the connector(s) and if necessary clean or fix them to make sure the connection is good.Check resistance:Turn ignition off. Remove connector from solenoid.Measure resistance between the two pins of the solenoid. Compare with specified resistance. Alternatively, checksolenoid function by applying battery voltage to its pins. The solenoid should “click”.Check supply voltage:Turn ignition off. Remove connector from solenoid.Start the engine and measure voltage between one connector terminal and the negative terminal of the battery. Checkthe second terminal. One of the two should equal battery voltage. If not check wiring and, if present, fuse(s) and relay.Check connection to ECU:Turn ignition off. Remove connector from solenoid and ECU.Measure the resistance between one of the two connector terminals and the corresponding terminal in the ECUconnector. Check the other terminal. One of the two should be < 1 ohm. If not check wiring